Guides
Lithium vs gel vs tubular battery: the best battery for solar
The battery is often the most expensive part of an off-grid or hybrid system, and the part that fails first when chosen badly. Compare batteries by usable energy and cost per cycle, not by the price tag.
The three types
- LiFePO4 (lithium iron phosphate): 51.2 V, 25.6 V or 12.8 V packs with a built-in battery management system (BMS), rated in datasheets at 6,000 cycles or more at 80–90% depth of discharge, no maintenance, wall or rack mounted.
- Gel / AGM (sealed lead-acid): no topping-up and a lower price, but only about half the capacity should be used each day to reach a reasonable life.
- Tubular (flooded lead-acid): robust and cheap per Ah, but needs distilled-water top-ups and ventilation because it gives off gas while charging.
Usable capacity: the number that matters
A 5.12 kWh lithium battery delivers about 4.6 kWh every day (90%). To get the same daily energy from lead-acid at 50% depth of discharge you need about 9–10 kWh of nominal capacity, for example four 12 V 200 Ah batteries (9.6 kWh). Lithium also holds a steady voltage and accepts fast charging, so the panels fill it even on short winter days.
Life and real cost per cycle
Lead-acid life drops quickly with deep discharge and heat. In hot climates with daily cycling, lead-acid banks often need replacing after a few years, while LiFePO4 is rated for more than a decade of daily cycles.
Cost per cycle = battery price ÷ (usable kWh × rated cycles). Even with a higher purchase price, lithium usually works out cheaper per kWh delivered over its life, and you avoid buying and transporting replacement banks.
Compatibility with your inverter
- Choose a battery whose CAN or RS485 protocol your inverter supports (Deye, Growatt, Voltronic, GoodWe and others)
- Match the voltage class: 48 V inverters take 51.2 V lithium
- Check the maximum charge and discharge current: 100 A × 51.2 V ≈ 5 kW, so a 10 kW inverter needs two batteries in parallel or a 200 A model
- For commercial sites use high-voltage racks or ESS cabinets
See our LiFePO4 batteries and matching hybrid inverters.
When lead-acid still makes sense
- Very small systems that cycle only occasionally (backup a few times a month)
- The lowest possible upfront budget, where replacements are easy to buy locally
For daily cycling, lithium is the better choice almost every time.
Frequently asked questions
How long does a LiFePO4 solar battery last?
The batteries we supply are rated in their datasheets at 6,000 cycles or more at 80–90% depth of discharge, which is well over 10 years of daily use when the battery is kept within its temperature and charging limits.
Can I mix lithium and lead-acid batteries?
No. Their voltages and charging profiles differ, so one type is always over- or under-charged. Replace the whole bank.
Is 12 V, 24 V or 48 V better?
48 V (51.2 V lithium) for anything above about 3 kW: lower current, thinner cables and less loss. 12 V and 24 V suit small systems and vehicles.